计算 · 学习 · 标准
Energy and Atmosphere / 能源与大气

Enhanced Refrigerant Management

Decarbonization · 脱碳
EAc7 Credit
EN

— ENHANCED REFRIGERANT MANAGEMENT EAc7 New Construction: 1–2 points; Core and Shell: 1–2 points

CN

Decarbonization · 脱碳 EAc7 New Construction: 1–2 分; Core and Shell: 1–2 分

Intent / 意图

EN

To reduce greenhouse gas emissions by accelerating the use of low-GWP refrigerants and promoting better refrigerant management practices.通过加速采用低 GWP 制冷剂并推广更佳的制冷剂管理实践,减少温室气体排放。

CN

 

Requirements / 要求

EN

Builds on EAp5; combine options up to 2 points. Option 1 No Refrigerants or Low GWP (1–2): Path 1 No Refrigerants (1 pt, no refrigerant equipment; Core and Shell ineligible if future equipment is needed), Path 2 Low GWP (1–2) where the weighted-average GWP of new equipment is ≤80% of benchmark for 1 point or ≤50% for 2 points (benchmarks: heat-pump water heaters 1400, HVAC/datacenter/process chillers 700, other process refrigeration 300; adjusted benchmarks allowed for low-charge equipment). Option 2 Limit Refrigerant Leakage (1, Core and Shell only with ≥20% capacity in scope) requires self-contained equipment (≥80% of total GWP, all GWP≥700 self-contained), brazed/press fittings, auto leak detection above 100 tCO2e, and an operational maintenance plan. Option 3 GreenChill Certification for food retailers (>20% gross area) earns Silver (1) or Gold/Platinum (2).建立在 EAp5 之上;可组合各方案至 2 分。方案 1 无制冷剂或低 GWP(1–2):路径 1 无制冷剂(1 分,无含制冷剂设备;核心与外壳若未来需设备则不符),路径 2 低 GWP(1–2)要求新设备加权平均 GWP ≤基准 80% 得 1 分、≤50% 得 2 分(基准:热泵热水器 1400、暖通/数据中心/工艺冷水机 700、其他工艺制冷 300;低充注设备可用调整后基准)。方案 2 限制制冷剂泄漏(1 分,仅核心与外壳且范围内容量 ≥20%)要求自带式设备(占总量 ≥80% GWP,所有 GWP≥700 均自带式)、钎焊/压接接头、>100 tCO2e 自动检漏及运维计划。方案 3 食品零售 GreenChill 认证(>20% 建筑面积)银级 1 分、金/铂级 2 分。

CN

 

Key Points / 关键要点

EN

Refrigerants can be over a thousand times more potent than CO2; mitigation grows critical as heat pumps proliferate through electrification.Benchmarks derive from the EPA 2023 AIM Act Technology Transitions Rule and align with EU F-Gas and Kigali Amendment limits.Low-charge equipment may use adjusted benchmarks based on refrigerant charge per unit of capacity.Option 2's maintenance plan sets leak-check frequencies scaled to charge size (e.g., quarterly above 500 tCO2e) and doubles testing if annual leakage exceeds 1%.Core and Shell may exclude future tenant equipment; district energy can be included in the GWP calculation when needed. 制冷剂温室效应可超二氧化碳千倍;随着电气化推动热泵普及,削减其影响愈发关键。基准源自 EPA 2023 AIM 法案技术转换规则,并与欧盟 F-Gas 及《基加利修正案》限值一致。低充注设备可按单位容量充注量采用调整后基准。方案 2 运维计划按充注量设定检漏频次(如 >500 tCO2e 每季度),年泄漏超 1% 则检测加倍。核心与外壳可排除未来租户设备;必要时区域能源可纳入 GWP 计算。

CN

 

^ Grid Interactive ← 工具箱 ← BD+C 首页 Planning for Zero Waste Operations v v