— ENHANCED ENERGY EFFICIENCY EAc3 New Construction: 1–10 points (8 required for NC Platinum); Core and Shell: 1–7 points (5 required for CS Platinum)
Decarbonization · 脱碳 EAc3 New Construction: 1–10 分 (8 required for NC Platinum); Core and Shell: 1–7 分 (5 required for CS Platinum)
To design buildings that minimize energy use, reducing the environmental damage from resource extraction, air pollution, and GHG emissions, and to facilitate the transition to a clean-energy future.设计能耗最低的建筑,减少资源开采、空气污染与温室气体排放带来的环境损害,并推动向清洁能源未来转型。
New Construction: Option 1 Prescriptive Path (1–10) combines Path 1 Regulated Loads (Case 1 ASHRAE 90.1-2019, 1–5 pts pre-2028 only; Case 2 ASHRAE 90.1-2022, 4–7 pts where 4 auto-awarded for prerequisite compliance, +1 per 25 incremental credits) and Path 2 Plug & Process Loads (1–4: Case 1 dashboard/management, Case 2 efficient ENERGY STAR equipment, Case 3 exceptional calculation 10–40% = 1–4). Option 2 Energy Simulation (1–10) uses ASHRAE 90.1 Appendix G PRM with the future source energy metric (electric site-to-source 2.0), replacing BPFs; Path 1 excludes on-site renewables (3–30% reduction = 1–10 pts), Path 2 includes them (10–100% = 1–10 pts). Core and Shell uses scaled point tables (Option 1 up to 7; Option 2 up to 7). Platinum requires 8 (NC) / 5 (CS) points.新建筑:方案 1 规定性路径(1–10)组合路径 1 受控负荷(案例 1 ASHRAE 90.1-2019,仅 2028 年前 1–5 分;案例 2 ASHRAE 90.1-2022,4–7 分,其中 4 分随先决条件合规自动获得,每多 25 个增量学分加 1 分)与路径 2 插头及工艺负荷(1–4:案例 1 看板/管理,案例 2 高效 ENERGY STAR 设备,案例 3 特殊计算 10–40% = 1–4 分)。方案 2 能源模拟(1–10)采用 ASHRAE 90.1 附录 G PRM 与未来源能源指标(电力站点-源系数 2.0)并替换 BPF;路径 1 排除现场可再生(降幅 3–30% = 1–10 分),路径 2 计入(10–100% = 1–10 分)。核心与外壳采用缩比积分表(方案 1 最高 7;方案 2 最高 7)。铂级须 8(新建筑)/ 5(核心与外壳)分。
The prescriptive path is a new LEED v5 alternative to energy modeling—no simulation required for regulated loads.Use the same ASHRAE 90.1 version and compliance method as EAp2 to streamline documentation.Option 2 deliberately prioritizes efficiency: Path 2 (including renewables) thresholds are more than three times stricter than Path 1.Eligible Section 11 measures for points are HVAC (H01–H07), SWH (W01–W09), lighting (L01–L06), and building mass/night flush (G07); envelope (E01) and renewables (R01) are rewarded elsewhere.Plug/process loads represent 30–50% of building energy and are addressed via dashboards, ENERGY STAR equipment, or exceptional calculations. 规定性路径是 LEED v5 新增的替代能源模拟之法——受控负荷无需建模。与 EAp2 采用同一 ASHRAE 90.1 版本与合规方法可简化文件。方案 2 刻意优先能效:计入可再生(路径 2)的门槛比排除(路径 1)严格三倍以上。可获积分的第 11 节措施为暖通(H01–H07)、生活热水(W01–W09)、照明(L01–L06)及建筑蓄热/夜间通风(G07);围护(E01)与可再生(R01)在其他条款奖励。插头/工艺负荷占建筑能耗 30–50%,可通过看板、ENERGY STAR 设备或特殊计算来体现。