计算 · 学习 · 标准
Indoor Environmental Quality / 室内环境质量

No Smoking

禁止吸烟
EQp2 Prerequisite
EN

— NO SMOKING EQp2 Required

CN

禁止吸烟 EQp2 必须满足

Intent / 意图

EN

To prevent or minimize exposure of building occupants, indoor surfaces, and ventilation air distribution systems to environmental tobacco smoke.

CN

防止或尽量减少建筑使用者、室内表面及通风空气输配系统暴露于环境烟草烟雾。

Requirements / 要求

EN

Achievement Pathways Points Existing Buildings N/A Prohibit Smoking Existing Buildings— Schools N/A Prohibit Smoking Existing Buildings— Residential N/A

CN

达标路径:既有建筑——禁止吸烟;学校——禁止吸烟;住宅——选项 1. 禁止吸烟 或 选项 2. 住宅套内分隔密封。均为先决条件,不计分。

EN

Option 2. Compartmentalization of Residential Units

CN

须满足以下全部要求:

EN

Option 1. No Smoking

CN

• 室内吸烟:禁止在建筑内部吸烟。

EN

OR

CN

• 室外吸烟:除指定吸烟区外,禁止在建筑外部吸烟;指定吸烟区须距所有出入口、室外进风口与可开启窗至少 25 英尺(7.5 米),或达到当地规范允许的最大距离。

EN

Option 2. Compartmentalization of Residential Units Comply with all of the following requirements:

CN

• 将禁烟政策告知建筑使用者,并落实执行措施或设置禁烟标识。

EN

Option 1. No Smoking Meet the requirements above.

CN

【学校】场地内全面禁烟,并须在用地红线处设置标明禁烟政策的标识。

EN

OR

CN

【住宅】选项 1. 禁止吸烟:满足上述全部要求。

EN

Option 2. Compartmentalization of Residential Units Meet the preceding requirements above for common areas. If smoking is not prohibited in the dwelling units and on private balconies, each unit must be compartmentalized to prevent excessive leakage between units:

CN

或 选项 2. 住宅套内分隔密封:公共区域满足上述要求。若住宅套内及私人阳台不禁止吸烟,则每套住宅必须做分隔密封处理,防止套间过量渗漏:

EN

• Indoor smoking: Prohibit smoking inside the building.

CN

• 对住宅套内所有外门与可开启窗做密封条处理,尽量减少室外渗漏;

EN

• Outdoor smoking: Prohibit smoking outside the building except in designated smoking areas located at least 25 feet (7.5 meters), or the maximum extent allowable by local code, from all entries, outdoor air intakes, and operable windows.

CN

• 对住宅套通往公共走廊的所有门做密封条处理;

EN

• Communicate the no-smoking policy to occupants of the building and have in place provisions for enforcement or prohibitive signage. Schools

CN

• 通过封堵墙体、顶棚与楼板的贯穿孔洞,以及封堵与住宅套相邻的竖向管井(含管道井、垃圾道、邮件投递井与电梯井),尽量减少烟雾及其他室内空气污染物在套间传递的不受控通路;

EN

• Prohibit smoking on-site. Signage must be posted at the property line indicating the no-smoking policy. Residential Only

CN

• 证明围护面(即围合该住宅套的全部表面,含外墙、分户墙、楼板与顶棚)在 50 Pa 压差下渗漏量不超过 0.50 cfm/ft²(2.54 L/(s·m²));或建立基线并证明每套住宅渗漏量改善 30%。

EN

• Weather-strip all exterior doors and operable windows in the residential units to minimize leakage from outdoors.

CN

 

EN

• Weather-strip all doors leading from residential units into common hallways.

CN

 

EN

• Minimize uncontrolled pathways for the transfer of smoke and other indoor air pollutants between residential units by sealing penetrations in the walls, ceilings, and floors and by sealing vertical chases (including utility chases, garbage chutes, mail drops, and elevator shafts) adjacent to the units.

CN

 

EN

• Demonstrate a maximum leakage of 0.50 cubic feet per minute per square foot (2.54 liters per second per square meter) at 50 Pa of enclosure (i.e., all surfaces enclosing the apartment, including exterior and party walls, floors, and ceilings) or establish a baseline and demonstrate a 30% improvement in leakage for each unit.

CN

 

^ Verification of Ventilation and Filtration ← 工具箱 ← O+M 首页 Indoor Air Quality Performance v v